Add to Cart
NO. | Items | Characteristics | Testing Methods | |
1 | Nominal Voltage | 24V | Follow | |
2 | Nominal Capacity | 10Ah | Follow | |
3 | Minimum Capacity | 9.5Ah | Follow | |
4 | Battery internal Impedance | Internal Impedance≤60mΩ, | Internal Impedance Testing Machine( HIOKI 3555,1kHz ) | |
5 | Shipment Voltage | 24V~28V | Multi-meter | |
6 | Dimension | L ngth | 180.5(±2)x76(±2)x166(±2)mm | Vernier caliper |
Width | ||||
Height | ||||
7 | Working Temperature | Charge | 0~50℃,45~85%RH | Temperature & Humidity Instruments |
Discharge | -20~60℃,45~85%RH | |||
8 | Storage empe ature & Humidity Range | Short: above one month | -20~+55℃,45~85%RH | Temperature & Humidity Instruments |
Medium: above three months | 0~+45℃,45~85%RH | |||
Long:above one year | +5~+30℃,45~85%RH | |||
9 | Allowed maximum continuous charge current | 6A | Multi-meter | |
10 | Allowed maximum continuous discharge current | 15A | Multi-meter | |
11 | Allowed maximum reverse charge voltage | NO Allowed | / | |
12 | Allowed maximum charge voltage
| 29.2±0.2V | Multi-meter | |
13 | Discharge cut-off voltage | 20±1V | Multi-meter | |
14 | weight | About:2.95 KG | electronic scale |
No. | Items | Standards | Testing Methods |
1 | Short-Circuit | NONE | Prohibit output electrode short circuit |
2 | Over Discharge Protection Test | The battery should be no remarkable breakage, distortion. Appearance and charge are normal. | Discharge the battery at the rate of 0.2C with the load of 30Ω for 24h . Charging for 10sec with specified adapter , and check the voltage(≥37V) |
3 | Impact Test | The battery should be no explosion or catch fire | Place a full charged battery on a flat and put a stainless steel stick (Diamond 7.9mm) in the middle of the battery upright . Beat the steel stick with 9.1Kg |