Add to Cart
NO. | Items | Characteristics | Testing Methods | |
1 | Nominal Voltage | 12.8V | Follow | |
2 | Nominal Capacity | 10Ah | Follow | |
3 | Minimum Capacity | 9.5Ah | Follow | |
4 | Battery internal Impedance | Internal Impedance≤100mR | Internal Impedance Testing Machine(1kHz ) | |
5 | Shipment Voltage | 12.8~13.6V | Multi-meter | |
6 | Dimension | Length | MAX: 80*80*142mm | Vernier caliper |
Width | ||||
Height | ||||
gross weight | 1.5kg | electronic scale | ||
7 | Working Temperature | Charge | 0~45℃,45~85%RH | Temperature & Humidity Instruments |
Discharge | -20~55℃,45~85%RH | |||
8 | Storage Temperature & Humidity Range | Short: above one month | -20~+55℃,45~85%RH | Temperature & Humidity Instruments |
Medium: above three months | 0~+45℃,45~85%RH | |||
Long:above one year | +5~+30℃,45~85%RH | |||
9 | Allowed maximum continuous charge current | 10A | Multi-meter | |
10 | Allowed maximum continuous discharge current | 15A | Pulse current 300A/2S | |
11 | Allowed maximum reverse charge voltage | NO Allowed | / | |
12 | Allowed maximum charge voltage | 14.6±0.1V | Multi-meter | |
13 | Discharge cut-off voltage | 9±1.0V | Multi-meter |
No. | Items | Standards | Testing Methods |
1 | Internal Impedance | Impedance≤100mΩ | Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test. |
2 | Nominal Capacity | 10Ah | Rest for 0.5~1 hour after fully charge, Using electrical loader to connect with the battery output port, and discharge with constant current 0.2C till it can’t discharge. Do the cycle three times, if there is one time that the discharge time is equal or more than 285minute , you can stop. |
3 | Short circuit protection | No load ability after short-circuit .comeback capability of loading after remove the lead away, | Short the pack with the lead (<50mΩ). If remove the lead away, connect the electronic loader with P+, P- of protection board again, so load ability comes back. |
4 | Allowed Maximum continuous charge Current | 10A | charging with allowed maximum current for more than 0.5h and the added temperature of battery pack less than 20℃. |
5 | Allowed Maximum continuous discharge Current | 15A | Discharging with allowed maximum current for more than 0.5h and the added temperature of battery pack less than 20℃. |
6 | Over Current Protection | 35~48A | Using electron load connect with output side, discharge with 35A for 2sec, Discharge with 48A for less than 40 ms; |
5. Warning & Tips
Please read and follow the specification and caution remarks on battery surface before use the battery. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. Shenzhen Topband Battery Co., Ltd. Describes is not responsible for any accidents caused by the usage without following our specification.
6. Deep cycle lithium ion battery 12V 10Ah dimension